Catalyst 6500的高可用性和冗余:
K: OK, clock 1 clock-inuse: in-use
· clock 2:
· clock 2 OK: OK, clock 2 clock-inuse:not-in-use
· power-supply 1:
· power-supply 1 fan-fail: OK
· power-supply 1 power-output-fail: OK
· module 1:
· module 1 power-output-fail: OK
· module 1 outlet temperature: 30C
· module 1 device-2 temperature: 35C
· RP 1 outlet temperature: 36C
· RP 1 inlet temperature: 37C
· EARL 1 outlet temperature: 29C
· EARL 1 inlet temperature: 30C
· module 3:
· module 3 power-output-fail: OK
· module 3 outlet temperature: 31C
· module3 inlet temperature: 27C
· module 5:
· module 5 power-output-fail: OK
· module 5 outlet temperature: 42C
· module 5 inlet temperature: 29C
· EARL 5 outlet temperature: 40C
· EARL 5 inlet temperature: 32C
· module 6:
· module 6 power-output-fail: OK
· module6 outlet temperature: 44C
module 6inlet temperature: 36C
· show environment power (CatOS) — 此命令提供关于系统电源情况和可用电源的详细信息。
· Cat6kCatOS showenvironment power
· PS1 Capacity: 1153.32Watts (27.46 Amps @42V)
· PS2 Capacity: none
· PS Configuration : PS1and PS2 in Redundant Configuration.
· Total Power Available:1153.32 Watts (27.46 Amps @42V)
· Total Power Availablefor Line Card Usage: 1153.32 Watts (27.46 Amps @42V)
· Total Power Drawn Fromthe System: 377.58 Watts ( 8.99 Amps @42V)
· Remaining Power in theSystem: 775.74 Watts (18.47 Amps @42V)
· Default Inline Powerallocation per port: 7.00 Watts (0.16 Amps @42V)
· Slot power Requirement/Usage:
· Slot Card Type PowerRequested PowerAllocatedCardStatus
· Watts A @42V Watts A @42V
· ---- -------------------------- ------ ------- ------ ----------
· 1 WS-X6K-SUP1A-2GE 138.60 3.30 138.60 3.30 ok
· 2 0.00 0.00 138.60 3.30 none
6 WS-X6348-RJ-45 100.38 2.39 100.38 2.39 OK
注意: 此示例 show environment power 命令输出使用带 PFC 和MSFC 的 Supervisor 引擎 1。
· show power(CiscoIOS 软件)— 此命令类似于 CatOS 中的 showenvironment power 命令。
冗余禁用:
Cat6kIOS#show power
system power redundancy mode = combined
system power total = 55.500A
system power used = 22.690A
system power available = 32.810A
FRU-type # current admin state oper
power-supply 1 55.500A on on
module 1 4.300A on on
module 2 4.300A on on
module 3 5.500A on on
module 4 5.500A on on
module 5 3.090A on on
module 6 5.400A off off (admin request)
冗余启用:
C6500-1> show power
system power redundancy mode = redundant
system power total = 1153.32 Watts (27.46 Amps @ 42V)
system power used = 674.52 Watts (16.06 Amps @ 42V)
system power available = 478.80 Watts (11.40 Amps @ 42V)
Power-Capacity PS-FanOutput Oper
PS Type Watts A @42V Status Status State
---- ------------------ ------- ------ ------------ -----
1 WS-CAC-1300W 1153.3227.46 OK OK on
2 WS-CAC-1300W 1153.3227.46 OK OK on
冗余启用,但其中一个电源不工作:
C6500-2# show power
system power redundancy mode = redundant
system power redundancy operationally =non-redundant
system power total = 3795.12 Watts (90.36 Amps @ 42V)
system power used = 1786.68 Watts (42.54 Amps @ 42V)
system power available = 2008.44 Watts (47.82Amps @ 42V)
Power-Capacity PS-FanOutput Oper
PS Type Watts A @42V Status Status State
---- ------------------ ------- ------ ------------ -----
1 WS-CAC-4000W-US 3795.1290.36 OK OK on
2 WS-CAC-4000W-US 3795.1290.36 - - off
- 北京机房搬迁改造公司,系统集成有哪些公司?-2019-11-04
- 如何打造一个安全的网络环境?政府要做到这四点-2019-11-04
- 北京办公室网络布线,综合布线施工价格-2019-11-04
- 深信服产品专业上网行为管理,安全设备有保障-2019-11-04
- 两年内网络安全市场规模将达千亿级别?来看看详细分析-2019-11-04
- 北京炫亿时代专业机房设备除尘,机房网络改造-2019-11-04
- 企业如何保障移动办公的安全性?移动办公存在的七大安-2019-11-01
- 北京深信服AC-1000-A400产品租赁购买,专业IT上网行为管理-2019-11-01
- 互联网企业软件开发如何才能没有漏洞?专业工程师给出-2019-11-01
- 如何避免APP的“越权”行为?要靠制定相关法律法规-2019-11-01